banner image

Installation and Debugging Methods for Linear Sliding Table

Installation and Debugging Methods for Linear Sliding Table

Linear sliding table is a kind of mechanical device that can provide linear movement, and is widely used in touch screen production equipment, optical instrument and other fields. The installation and debugging of a linear sliding table are important steps to ensure its normal operation and accuracy, and the following methods need to be followed:
Preparation before installation of linear sliding table. Before installation, it is necessary to check the appearance of the linear slide for damage or contamination, as well as for loose or missing parts. If there are problems, they need to be replaced or repaired in a timely manner. In addition, it is necessary to clean and lubricate the guide rails and ball or roller cages of the linear slide to reduce friction and wear.
Selection of installation position for linear sliding table. The installation position of the linear sliding platform should be in a flat, stable, vibration free, strong magnetic field free, and corrosive gas free environment. The installation direction of the linear sliding platform should be consistent with its movement direction and perpendicular or parallel to the horizontal plane. If multiple linear sliding platforms need to be installed, their parallelism and verticality should be ensured.
Selection of fixation method for linear sliding table. The linear slide can be fixed to the base or bracket by means of bolts, screws, or fixtures. When fixing, attention should be paid not to be too tight or too loose to avoid deformation or looseness. After fixation, the linear sliding table should be checked for looseness or deviation, and if so, it should be adjusted in a timely manner.
Selection of electrical connection method for linear sliding table. The linear slide can be connected to devices such as power supplies, controllers, or sensors through cables, plugs, or interfaces. When connecting, attention should be paid to whether the electrical parameters match and whether the contact is good. After connecting, it is necessary to check if there is any abnormal sound or fault indicator light on the linear slide. If there is, it should be promptly resolved.
Debugging method for linear sliding table. Before debugging, you should first read the user manual of the linear sliding table to understand its working principle, parameter settings, operating methods, and other contents. When debugging, no-load running tests should be conducted first to check whether the linear sliding table has jamming, jumping, deviation, and other phenomena, as well as whether the running speed and accuracy meet the requirements. If there are problems, they should be adjusted or replaced in a timely manner. After passing the no-load running test, conduct a load running test to check whether the linear sliding table can withstand the predetermined load and maintain stable and accurate movement. If there are problems, they should be adjusted or replaced in a timely manner.
Precautions for the use of linear sliding tables. When using a linear slide, the following precautions should be observed:
Do not exceed the rated load, speed, and travel range of the linear slide.
Do not forcibly stop or change the direction of motion of the linear slide during operation.
Do not allow foreign objects to enter the guide rails and ball or roller cage of the linear slide.
Regularly clean and lubricate the guide rails and balls or rollers of the linear sliding table